News of v1.95
----------
- New sound play function, repeat...
- I remake the complete function (because Kinboat one is very slow) to show the PCX file, now HPI Manager
	show them quicker, and you can see large PCX picture. There is a zoom too. And to move the images in the
	bottom-left hand corner keep your mouse pushed and move it.
- New viewing file options. (in "Set programs locations" menu)
- Quick GAF viewer, it's the same program than Quick 3DO viewer but for 
	the 3DO file. Now HPI Manager only need a Quick MAP viewer and a Quick COB viewer. (comming soon)
- Export unit into one HPI function now available.
- Sometimes, HPI Manager deleted the c:\XXX files... fixed, an sorry for the problem...
- Add a VERY VERY small help file (just for testing if it work under win95). If yes, i will do a complete help.
- more bug fix...

IMPORTANT NOTE !
----------------
If HPI Manager isn't closed normally, or it crash, the temporary directory isn't
deleted, so go to HPI Manager path and delete it manually (ex : c:\program files\HPI Manager\tempX ::> X=1,2,...10)

|-------------------|
|QUICK PREVIEW OF V2|
|-------------------|
- Quick MAP Viewer
- Quick COB Viewer
- Perhaps an Help
- During modifying an HPI, you'll can add or remove files
- Maybe creating HPI

-----------------------------------------------------------------------------
-----------------------------------------------------------------------------

News of v1.9
----------
- fixed the crash with the unpack several HPI function
- Add "Open new HPI file once finish" option in unpack several HPI function
- add the filename and path verification in unpack several HPI archive function.

-----------------------------------------------------------------------------
-----------------------------------------------------------------------------

New Features of v1.9 beta :
----------------------
- You can now uncompress several HPI in one time. In a directory or into a new HPI.
- HPI Manager make a diferent temporary folder each time you run it. That mean you can now modify 
several HPI at the same time without having an error.
- For the moment, you can run only 10 copy of HPI Manager at the same time...sorry
- You can view 3DO without a 3DO program, i have made a quick 3DO viewer.
- Custom export to the unit viewer.

Bug fixed in v1.9 beta :
-------------------
- When you bouble clic on a PCX file, HPI Manager launch the default PCX viewer installed on your computer if you have one.
- Now you can modify ten HPI at the same time without errors.
- after msaving a modified HPI, if you want to modify it again, there was an error...fixed.
- Sometimes, the sound not work...fixed
...lots more

-----------------------------------------------------------------------------
-----------------------------------------------------------------------------

New Features of v1.2 :
----------------------
- Several mode to view files
- Collapse or expand the HPI path view 
- At the status' bar left, HPI Manager state or action is described
- The last 10 opened archive are listed at the end of the file menu
- New tool bar which is custmisable
- You can now see hex dump of file

Bug fixed in v1.2 :
-------------------
- The HPI file was not registered properly with HPI Manager
- When you open an HPI and modify it whihout saving it, if you open an other HPI the
	menu was set properly
- the file MSVB60.DLL was missing... sorry
- many other...

-----------------------------------------------------------------------------
-----------------------------------------------------------------------------

New features of v1.1 : 
----------------------
- Repack HPI archive in every mode (no, LZ77, ZLIB)
- Save unit picture as BMP picture by clicking on it
- Modify HPI file without have to unpack and repack it after, 
	HPI manager do it automatically. Click in menu on Modify archive 
	then open file in HPI manager and save it in notepad, gaf builder..
	After modification, click save modification in mode...

Bug fixed in v1.1 :
-------------------
- the picture window was too big : fixed
- when you try to extract a directory which exist, HPI Manager crash : fixed
- You can't export to Unit Viewer unit from .FBI file (in uppercase) : fixed
- Some of the menu or other was in french...traduction finished.